Nonlinear Spectroscopy and Magneto-Optics

From Physics 111-Lab Wiki

Jump to: navigation, search

All pages in this lab. Note To print Full Lab Write-up click on each link below and print separately


I. Nonlinear Spectroscopy and Magneto-Optics (MNO)

II. MNO Pre Lab Questions and Staff Sign Off Sheets.....PRINT, FILL THIS OUT, Turn it in


III. LabView Program Descriptions

IV. Photodiode Circuit

V. Tuning the Laser

VI. Optics Tutorial

VII. Magnetic Shielding Diagram

Reprints and reading materials can be found on the Physics 111 Library Site



Acknowledgment and Disclaimer. This material is based upon work supported by the National Science Foundation under Grant No. 9750873. "Any opinions, findings and conclusions or recommendations expressed in this material are those of the author(s) and do not necessarily reflect the views of the National Science Foundation (NSF)."

D. Budker, D. Orlando, V. Yashchuk, S.P. Davis and Laboratory Staff

Contents

Before The Lab

Before using the apparatus in this experiment, you must complete training in the safe use of lasers detailed on the Laser Safety Training page. This includes readings, watching a video, taking a quiz, and filling out a form.


Discuss the Physics about this experiment with the faculty or the GSI's in the 111-Lab before starting.

You should keep a laboratory notebook. The notebook should contain a detailed record of everything that was done and how/why it was done, as well as all of the data and analysis, also with plenty of how/why entries. This will aid you when you write your report.


View the introduction, part I. video and the introduction, part II video, discuss the pre-lab questions with an instructor, and have the MNO Pre-Lab turn-in signed with report. You may find it useful to review principles of optics in the Optics Tutorial.

Note on the intent and scope of this laboratory manual

This manual is intended to provide a general guidance for the lab. It is not designed to explain all the physics necessary for understanding this experiment, nor is it a "cook-book" telling you exactly which buttons to press, etc. It is up to the student to become familiar with the necessary material in the reprints, and to figure out the exact procedure necessary for completion of the assignments in the lab. Talk with an instructor often, but not until you have given the physics and procedures some thought first. We are here to instruct and help, but not to do your thinking for you.

=Prerequiste Reading Materials

General

  1. W. Demtroder. Laser Spectroscopy. Springer, 1996.
  2. Optics Tutorial

Prerequisite Reading Material

  1. Diode Lasers: EOSI Owner's Manual "2010 External Cavity Diode Laser:", EOSI, Inc. (Read p. 13-30, plus the diagram and specifications at the end.)
  2. Fabry-Perot Spectrum Analyzers: "Technical Memorandum on Fabry-Perot Interferometry". Burleigh Instruments. Use this article to get some definitions and formulas. Most intermediate optics texts have a detailed analysis of how the fringes are formed, and a derivation of the transmission function.
  3. Saturation Spectroscopy: D. W. Preston, "Doppler-free saturated absorption spectroscopy: Laser spectroscopy", Am. J. Phys. 64(11), (1996). p. 1432-1436. (A fairly good introductory article (none better around).)
  4. Saturation Spectroscopy: D. W. Preston and C. E. Wieman, "Doppler-free saturated absorption: laser spectroscopy". An advanced laboratory write-up (09/1994; unpublished), p. 1-32. A more detailed version of the above.
  5. Diode Lasers: C. E. Wieman and L. Hollberg, "Using Diode Lasers for Atomic Physics", Rev. Sci. Instrum. 62 (1), January 1991; p. 1-21. (A good article if you want to know how diode lasers work and how they are used.)
  6. D. Budker, D. J. Orlando, and V. Yashchuk, "Nonlinear Laser Spectroscopy and Magneto-Optics:", Am. J. Phys. 67, 584 (1999). (Covers the physics in the latter part of the lab.)
  7. Michael Lang. "External Cavity Designs Satisfy Stringent Demands"; Laser Focus World; June 1996, Pg. 1432-1436;
  8. T. J. Sumner, J. M. Pendlebury, and K. F. Smith "Conventional Magnetic Shielding"; J. Physics D. Applied Physics 20 (1987) Pg. 1095-1101
  9. L. M. Barkov, D. A. Melik-Pashayev and M. S. Zolotorev "Non-Linear Faraday Rotation in Samarium Vapor"; Optics Communications Vol. 70, No. 6, 15 April 1989
  10. Dimirty Budker, Valeriy Yashchiek, and Max Zolotorev "Resonant Magneto-Optical Rotation: New Twists in an Old Plot"; National Science Division Dec 1997; LBNL-41149, UC-000 Preprint

Note on Safety (please do not ignore)

There are two major sources of danger in this experiment: laser radiation (780 nm, 10 mW continuous wave) and moderately high voltages present on some of the equipment (250 VDC at the scanning confocal Fabry-Perot (F-P) spectrum analyzer). The onset of permanent damage to the eye is at 10 mW. Any potential difference greater than 30 volts is potentially shocking. Please observe the following simple rules that will help you stay out of harm's way:

  1. When the laser is on, always wear the protective eyewear provided. The laser goggles available for this experiment absorb the infrared (IR) radiation from the laser and transmit visible light. Therefore, they will not hinder general visibility. While you are working on beam alignment you can use a night-vision device converting IR into visible light to see the laser beam without any danger. Please refer to Appendix IV about optics.
  2. A general rule for laser operators is to remove watches and jewelry because laser beams can get accidentally reflected in an uncontrolled fashion from watches or rings when a hand crosses the laser beam path.
  3. Do not look directly into the laser beam under any circumstances.
  4. This is the most important rule: always use common sense and think before doing anything.

Introduction

The laser spectroscopy has been useful in a variety of applications throughout the years. It has been used in medicine, chemistry, material science, environmental research and many other fields. Combustion processes, atmospheric monitoring, water and vegetation surveillance, and medical diagnostics are but a few applications of the broader spectrum.

The "Nonlinear Spectroscopy and Magneto-optics" experiment is a good introduction to laser spectroscopy. The experiment itself will consist of three parts whose set up is fairly simple. In the first part you will learn a little about the diode laser and its operation. As you get familiar with the laser's operation, you will test the laser's performance using the Fabry-Perot spectrum analyzer. In the second part of the experiment you will record and analyze Doppler-broadened laser induced fluorescence and Doppler-free saturated absorption spectra of the rubidium. In the third part of the experiment we will investigate the near-resonant magneto-optical rotation. To get familiar with these concepts it is strongly recommended that you read the "Nonlinear Laser Spectroscopy and Magneto-Optics" article written by Dmitry Budker, Donald Orlando, and Valery Yashchuk. This article covers everything you need to know to complete this experiment. It is provided in the reprints for your convenience.

Apparatus

In this lab we are going to use EOSI 2010 External Cavity Diode Laser. This is a tunable, narrow line width (100-kH) laser that has the capability of changing the wavelength range internally. Please be very gentle with this unit and do not turn any knobs unless instructed to do so. This laser system is very expensive that cost us about 16 thousand dollars.

The optical set up for this experiment is fairly simple. The laser beam coming from the EOSI 2010 LASER passes through a Diaphragm Iris and is split into several beams so that we can set up all three parts of the experiment using one beam at all times. The splitting of the beam is done using the beam splitters. The beam splitters in our lab are just pieces of microscopic cover glass attached to the adjustable mirror mounts. The optical set up for this experiment is shown in the Figure 1. As you read this section, refer to both the diagram in Figure 1 and also the actual optical set up on the table. Keep in mind that as you follow the actual setup, you must be careful not to touch anything. Even slightest movement of the mirrors, beam splitters and other parts will result in misalignment of the experiment not to mention that you will leave fingerprints all over the mirrors and beam splitters. If that happens, you will create more tedious work for yourself and others trying to align the components.

The first beam splitter (BS-1) is used to split the incoming laser beam into two beams. One of the beams will be used for the Fabry-Perot spectrum analyzer. The other beam will be split by BS-2 and BS-3 to be used in Doppler-free saturation spectroscopy. Finally, the laser beam coming out of BS-3 will be split furthermore by BS-4 for the magneto-optical part of the experiment. The beam coming out of BS-4 will not be used in this experiment and is blocked by the beam stopper. The optical setup of each individual part of the experiment will be discussed in greater detail in the procedure section. Roughly speaking, the laser beam coming out of the BS-1 for the Fabry-Perot part of the experiment passes through the Diaphragm Iris and goes into the Fabry-Perot spectrum analyzer. The output of the spectrum analyzer is connected to the photodiode sensor (PD-4). The laser beam coming from BS-2 for the laser-induced fluorescence part of the experiment passes through the optical chopper and then through the center of a Rubidium cell. This beam is then blocked by a beam stopper. A second beam coming from BS-3 is reflected by a mirror, M1 as shown in figure 1. The reflected beam also passes through the rubidium cell but in the opposite direction. This beam is then reflected by another mirror, M2, and is sent to a Photodiode sensor, PD-3. Another photodiode sensor, PD-5 is placed next to a rubidium cell as shown in figure 1. Finally, in the magneto optical part of the experiment, the laser beam coming from BS-4 is passed through two polarizes. It is then passed through another rubidium cell that is placed inside magnetic coils (the cell with coils is shielded). The laser beam exits the rubidium cell and enters the polarimeter, PBS that splits the beam into two. The two beams enter two photodiode sensors, PD-1 and PD-2. On the side of the shielded cell with coils is located another photodiode, PD-6.

Photodiode circuit

In this lab, we use several silicon photodiodes to measure the intensity of laser beams and of atomic fluorescence light. The simple circuitry that we use (the photodiode bias and load resistor box) is shown in Figure A2. Here, the photodiode operates in the photoconductive mode in which a reverse bias is applied to the diode and no current is flowing through the circuit in the absence of light (neglecting the dark current, which actually becomes important in small-signal applications). In the absence of current, there is also no output voltage across the load resistor. When a photon strikes the photodiode, it creates an electron-hole pair in the conductivity band in the carrier-depleted zone of the photodiode's pn-junction. The quantum efficiency of this process may reach nearly 100 %, meaning that there is one pair produced per incident photon. The charges then flow through the load resistor upon the action of the bias voltage, thus producing output voltage.

Fig. A2.

Schematic of the photodiode bias and load resistor box

PhotoDiode-10DP data Sheet


Figure 1: Diagram of the optical set-up

All six photodiode sensors are connected to photodiode load resistors. The PD-5 used in the Diode Scan section of the lab is connected to a 1MΩ PD Load Resistor. The output of that load resistor is then connected to ACH2 input of the LAB PC 50 PIN I/O BREAKOUT BOX. The 50 Pin Breakout Box is used to input BNC cable data to the DAQ card installed in the computer. See the diagram of the electrical connections in Figure 2. The Figure 2 shows the connections for the Diode Scan part of the experiment. The B-Field Scan section of the lab will use connections shown in Figure 3.

Referring to either Figure 2 or 3, you can see that the PD-4 is connected to the 100KΩ Load Resistor whose output is connected to ACH0 of the Breakout Box. The PD-3 is also connected to 1MΩ Load Resistor whose output will be connected at some point of the experiment to SR830 DSP Lock-In amplifier (do not connect the PD Load resistor to the Lock-in yet). Lock-in amplifiers are used to detect and measure very small AC signals. Accurate measurements can be made even when the small signal is obscured by noise sources. Lock in amplifiers use a technique known as phase-sensitive detection to single out the component of the signal at a specific reference frequency and phase. Noise frequencies other than the reference frequency are rejected and do not affect the measurement. In our experiment we will connect Channel 1 Output of the Lock-in to the ACH1 Input of the Breakout Box. The Ref In of the Lock-in is connected to the SR 540 Chopper Controller's "f"/f diff Input. The SR 540 Chopper Controller controls the optical chopper that chops the laser beam coming from BS-2. The PD-2 is connected to the 100kΩ Load resistor whose output goes to ACH4 of the Breakout Box. The PD-1 is also connected to the 100kΩ Load Resistor whose output is connected to ACH3 of the Breakout Box.

The 2010 Laser Input is connected to 2010 Electronic Control Unit (ECU) Laser Output. The 2010 ECU allows you to control the lasers' current input, wavelength, temperature, and other parameters. The 2010 ECU is connected to the 2010 SERVO LOCK via two cables: one connecting current inputs on both of the units and the other connecting PzT inputs on both the units. The 2010 Servo Lock is used for the stability of the laser. The Feed Forward Input of the Servo Lock can be connected in two different ways to the DAC0 Input of the Breakout Box. One way is to directly connect it to the DAC0 Input of the Breakout Box. Another way is to connected it through the 1:10 DIVIDER (Little Gold Box) to the DAC0 Input of the Breakout Box (see figure 2). The 1:10 Divider allows you to "zoom-in" on your spectrum for finer detail.

In the Diode Scan section of the lab, the DAC1 of the Breakout box should be directly connected to the Input of the 2010 Servo Lock. However, when doing the B-Field Scan, the DAC1 should be connected to the magnetic coils in ether of the two ways. One way is to connected it through a 2.5 kΩ Load Resistor (Little Blue Box). Second way is to connect it to the Input 1 of the COIL DRVER whose OUTPUT 1 should be connected to the magnetic coils. The Monitor 1 input of the Coil Driver should be monitored by a DMM. The 2.5 kΩ resistor is there so that you can also "zoom-in" on your spectrum for better detail. See Figure 3 for the diagram.

Figure 2: Block Diagram of the electrical connections for the Diode Scan part.
Figure 3: Block Diagram of the electrical connections used in the B-Field scan section of the lab.

Procedure

Part 1: Laser Operation, Spectrum Analyzer

In this part, you will learn to operate the diode laser, familiarize yourself with various parameters of the laser output, and learn to use the scanning confocal Fabry-Perot interferometer. Prior to turning on any of the equipment or changing any of the electrical connections, you should carefully read the relevant operating instructions and watch the videotape. Again, please keep in mind that you are dealing with expensive equipment (e.g. \approx$16 k for the EOSI diode laser system) that can be damaged quite easily.

Operating the Laser

  1. Use the laser manual and the diagrams provided in the manual to identify all parts of the laser system: laser head (where the laser actually is), electronic control unit (ECU), servo-lock, wavelength control knob on the laser (tuning knob), laser output port. Read about the controls and indicators on the ECU.
  2. Check all connections between the laser system and other components shown in Fig. 1 and Fig 2. They should all be in place, but check them anyway. Again, be careful not to touch the optical instruments. It is a pain to line them all up!
  3. Check to see that the laser system is turned on. The key in the back of the ECU should be horizontal. The system is left on all the time, even while the laser itself is not operating. With the "Laser ON/OFF" button still unlit, press the CURRENT button to awaken the ECU from SLEEP. On the left side of the screen a message will appear showing: >IOP 50.03 mA >IPD 2.05 mA. Turn the ADJUST knob, to set the laser current IOP to 50 mA (never exceed the maximum laser operating current \approx75 mA). Press the CURRENT button again, and set the maximum current to 75 mA. Laser power is approximately proportional to (I-Ithr), where Ithr\approx19 mAis the lasing threshold current. On the right side of the screen will be OFF (laser off) and _ 23.0 (temperature of the laser).
  4. Make sure you know where the beam will go before you turn on the laser.
  5. Turn on the laser by pressing the "Laser ON/OFF" button. Observe the laser beam (goggles on) using the IR visualization card, or the night vision viewer and a piece of paper. You can observe where the beam is going without actually blocking it by using a piece of lens paper and the night vision telescope. This is especially helpful around mirrors or other tight spots.

Q. What is the shape and size of the laser beam? Why is it elongated in one direction? By observing the beam size at different distances from the laser, roughly estimate the angular divergence of the beam. Is it close to being diffraction limited (meaning the minimum divergence with a given beam cross-section, sine theta ~ wavelength/beam diameter?

As shown on the diagram of the optical set-up (Fig. 1), small fractions of the laser beam are split with beam splitters mounted on adjustable mirror mounts. The first beam splitter directs laser light through a scanning confocal Fabry-Perot interferometer. Reprints for this lab contain a technical memo on Fabry-Perot interferometry written by Burleigh Instruments - a commercial manufacturer of F-P spectrum analyzers. In this experiment, we use a homemade F-P.

In this lab, the FP serves two purposes. The first is as a frequency marker, so we know how far apart the peaks are when we take a spectrum. For reference, the peaks on the FP spectrum are spaced 1.50 GHz apart. The second is to see how well the laser is working. If the peaks are periodic, then the laser is working well, but if the peaks are absent or scattered around, that means either the laser is "mode hopping" or the FP is not aligned correctly. Also, make sure that you are not driving the FP with the signal generator. This causes the cavity length to oscillate and would produce irregular scans.

6. In order to observe the transmission pattern of the F-P analyzer, check to see that the appropriate connections are made. Everything should be already there, but check it anyway. As shown on the diagram in the Figure 2, the photodiode (PD-4) output of the F-P analyzer is connected to a photodiode 100 kΩ Load resistor. (The circuit is described in Photodiode Circuit). The output of the PD Load resistor is connected to the ACH0 input channel of the DAQ board (the BREAKOUT BOX). Connect the DAC0 from the Breakout Box to the Feed Forward of the 2010 Servo Lock. Connect the DAC1 of the Breakout Box to the Input of the 2010 Servo Lock. Make sure the laser beam passes straight through the F-P spectrum analyzer. If it does not, you need to align it using the night vision viewer or the IR card. Be very gentle when aligning the optical instruments. When aligning the optics, use Figure 1 as your guide. Make sure you understand where the laser beams must enter and exit.

In this lab, the experiment control and data acquisition are performed using a PC computer equipped with data acquisition and control card (DAQ). Input to and output from the card are accomplished through a BNC breakout box. The process is controlled by a LABVIEWTM program "Diode Scan for 111 lab.vi. A description of this program is given in LabView Program Descriptions, and a shortcut to it can be found on the DESKTOP of the computer dedicated to this experiment.

7. Set up the "Diode Scan for 111 lab.vi" program to do a 2Vpp scan and obtain the transmission spectrum of the F-P analyzer. You should refer to LabView Program Descriptions for information on all the buttons and what they do. To start with you can use 1000 points per scan, 15 acquisitions per scan point, 500 points per sec acquisition rate, and -1V minimum. What can you say about the laser mode structure based on your result?

Aligning the Fabry-Perot Interferometer

Do not do this section unless you are absolutely sure that the Fabry-Perot Interferometer needs to be aligned. This section should be only used when all other things have failed to fix the problem (i.e. the laser beam is aligned, you have the proper connections and etc.). Before you start aligning the Fabry-Perot Interferometer, talk with the staff members and explain why you think the F-P Interferometer needs to be aligned. Please refer to the Optics Tutorial.

Instead of varying the frequency of the laser and observing the F-P spikes on Labview, you can use a signal generator to apply a changing voltage to the PZT in the interferometer while keeping the laser at a fixed frequency. This changes the length of the resonant cavity periodically. You can then make the necessary adjustments and watch the shape and of the F-P spikes change on the scope.

  1. Connect the output of the high voltage amplifier to the PZT on the Fabry-Perot interferometer.
  2. Connect the Wavetek signal generator output to the input of the high voltage amplifier and to the scope.
  3. Connect the output of the Fabry-Perot interferometer diode (the cable that normally goes from the Fabry-Perot through the variable resistor box to ACH0) to the other channel on the scope.
  4. Set the Wavetek to a 100 Hz triangle wave and look at both channels on the scope at the same time.
  5. Adjust the amplitude of the Wavetek or the output offset on the high voltage amplifier until the Fabry-Perot spikes are not overlapping.
  6. Adjust the time scale on the scope so that only 1 or 2 Fabry-Perot spikes are displayed.
  7. Adjust the alignment of the beam splitter, the size of the aperture, and the height of the Fabry-Perot interferometer so that the Fabry-Perot spikes are as large as possible and as symmetric as possible. Please refer to the Optics Tutorial.
  8. If the peaks are still irregular, you may have to change the temperature of the laser by half a degree or so. Do not change the temperature yourself. Call for assistance from Don or an instructor.

Determining the Voltage to Frequency Conversion Factor

The wavelength of the laser is displayed on the ECU Laser Controller to the nearest tenth of a nanometer. However 0.1 nm corresponds to 3x1018Hz and the frequency intervals we are interested in are on the order of 100 MHz. However the 1.5 GHz frequency markers from the FP combined with knowledge of the laser control voltage difference between two peaks allow you to derive a conversion between laser control voltage (which LabView records) and laser frequency.

Once the F-P interferometer is aligned and the laser is working correctly, take a scan over a frequency range that will sweep through a number of FP markers (a 3 V p-p scan should be sufficient). Save the scan to file then open and plot the data in Excel or other programs you prefer. Calculate the voltage spacing between successive FP peaks to get a feel for how the laser's frequency changes with voltage.

The laser's frequency as a function of control voltage may not be a perfectly linear relationship. It should be sufficient to average these voltage intervals to come up with a conversion factor in units of Volts per 1.5 GHz which can be inverted simplified to convert to the desired units of GHz/V. If this linear approximation of frequency as a function of voltage is not accurate enough, one can derive a quadratic expression for frequency as a function of voltage, however this is probably unnecessary.

Important: When using the 1:10 zoom resistor the voltage to frequency conversion factor is different. To determine the new conversion factor repeat the process above with the zoom resistor connected. With the resistor you will need to scan at least 5 V p-p in order to fit two FP spikes on one scan.

How to tune the laser

Before manually tuning the laser (which is done with the tuning knob on the back of the laser box (see Fig. 1 of the laser owner's manual), set the laser wavelength display to the appropriate USER mode. Refer to pp. 20-21 of the laser manual. Bring up the CAL menu and make sure that the USER mode is selected, then press the WAVELENGTH knob.

  • Are you SURE you need to re-tune the laser? If the WAVELENGTH reading is 780.2 nm \pm 0.4 nm, then the laser is likely already tuned. Look for other possible problems first, as the tuning procedure may take a while.

On the Diode scan program, set values for a scan which has an average voltage of 0 (e.g., Vmin= -1 and 2 Vpp), and press Start ONCE. (This will only set the values, but won't actually do a scan.) The reason for doing this is that even though the program is not scanning, it is still applying the average voltage to the servo-lock. We want it to be applying 0V to the servo-lock while we do this adjustment so that it will give us the widest range later. The Servo can only take in and put out a finite voltage range. On the Servo-lock, turn the "meter select" knob to "output", and turn the bias knob until the display reads zero. This eliminates any output offset.

Turn the tuning knob on the laser until the wavelength reading is near 780.2nm. (It will flicker back and forth about \pm 0.2nm, which is normal) Now, while using the night vision camera, VERY SLOWLY turn the tuning knob until you see some light beams flicker in the 87/85 cell. Due to the behavior of the laser, this may only happen if you pass the point in one direction, but not the other. Since this knob is such a course adjustment, the flicker means you went through all the peaks really quickly. Try to leave the knob on a position so that you can see a constant glow in the tube. It doesn't matter which peak you are on, but some are brighter than others.

Part 2: Tuning the laser to resonance, laser-induced fluorescence spectra

In this part of the lab, you will tune the laser to the rubidium D2 resonance (2S1/2\rightarrow 2P3/2) at 780.2 nm and observe laser-induced fluorescence as the laser frequency is scanned across the atomic resonance.

The laser system has a built-in wavemeter (i.e. a device that measures wavelength). Based on the mirror position (determined with a precision built-in decoder) and the type of the diffraction grating used, a microprocessor calculates an approximate wavelength at which the laser is operating. This rough estimate can be significantly improved after an atomic resonance has been found with this system. Now, one can display absolute wavelength with uncertainty of \pm0.1 nm, which is more than adequate to place the laser frequency within a smooth electronic wavelength tuning range from an atomic resonance.

  1. Tuning the EOSI diode laser to resonance can be very time consuming since \pm0.1 nm corresponds to a frequency range on the order of 1018 Hz and the frequency range of 10 V p-p scan is on the order of 1010 Hz. The calibration of the laser you are using has already been performed. If things are working properly, do not adjust it! You can spend DAYS trying to find the correct tuning. If you are absolutely sure that the laser needs re-tuning, call for help.
  2. Our goal now is to observe laser-induced fluorescence from Rb atoms in a vapor. Looking at the diagram in Figure 1, we are going to use a laser beam that is coming off of the beam splitter BS-1. The following is already set up on the optical table and all you need is to check that everything is in place. Please refer to the Optics Tutorial. Do not dismount any of the components from the table and try to avoid touching the optical instruments unless you are in the process of aligning the beam. The laser beam coming from BS-1 should pass through a beam splitter BS-2 that splits the beam into two. One of the beams passes through, and the other splits off at somewhere less than 90 degree angle towards an optical chopper. Passing through the optical chopper, the beam enters a rubidium cell (the one outside the magnetic shield). The beam exits the cell and is then blocked by a beam stop. The cell mounting and BS-2 can both be adjusted if necessary. As indicated on the diagram, there should be a photodiode PD-5 placed facing the cell. This photodiode has a 780 nm interference filter attached to the front side of the diode to reduce pick-up from room lights. The output of the photodiode is connected to the 1 MΩ Load resistor input. The output of the PD Load resistor is connected to the ACH2 input of the DAQ BNC connector box (the Breakout Box). The second beam that passes through the BS-2 is split in to two once again by a beam splitter BS-3. One of the beams passes right trough the BS-3 and the other is reflected off of it. The reflected beam is then sent to a mirror M1 where it is reflected to pass trough the rubidium cell, but in the opposite direction. This beam exits the rubidium cell and is reflected once more by another mirror, M2. Finally this beam enters a photodiode sensor PD-3. The output of the PD-3 is connected to the PD Load Resistor. At this time, nothing is connected to the output of this load resistor, but in the next section you will connect it to the Lock in Amplifier. Connect the DAC0 from the Breakout Box to the Feed Forward of the 2010 Servo Lock. Connect the DAC1 of the Breakout Box to the Input of the 2010 Servo Lock. Start the Diode Scan LabView program, and perform a laser scan. If you do not see anything in the diode scan program, then it is very likely that the laser beam needs to be aligned. Please refer to the Optics Tutorial.

Aligning the laser induced fluorescence set up.

To align the laser beam there is no right or wrong way to do it. It can be very frustrating procedure, but do not despair. Please refer to Appendix IV about optics. Here are few tips on how to align the laser beam for this part of the experiment. Start with the probe beam from BS-3. Block off the pump beam from BS-2 for now by inserting a piece of paper in its path, so this beam does not get confused with the probe beam. Position the probe beam coming from BS-3 in the center of the round mirror M-1. Use the IR (infrared) Card to see where the beam is. The night vision telescope (NVT) can be helpful in position the beam exactly. Keep in mind that the focal length of the NVT is about 5 to 6 feet, so you need to stand far from the object you want to view. Adjust the mirror mounts to position the reflected beam near the vertical edge of the square mirror M-2. The beam should be centered in the vertical direction. Now adjust the position of the vapor cell VC-1, so the probe beam goes approximately through the centers of the input and output windows. Since there are no convenient adjustments of the mirror M2, adjust the position of the photodiode PD-3 until the beam is centered on it. Now, remove the piece of paper blocking the BS-2 and cover the beam from BS-3 to avoid confusion. Position the beam from BS-2 so that it passes directly through the center of the vapor cell (you can turn off the optical chopper for now but don't forget to turn it back on). It is helpful to use IR card to position the beam and then view it with the night vision telescope (NVT). The beam should go straight through the cell and fall onto the beam stop as shown in the diagram in Figure1. Now, remove all the pieces of paper blocking the beams. Make sure the two beams intersect inside the vapor cell. This completes the alignment of the probe beam.

Q. How is frequency scan accomplished in this laser? Consult the EOSI laser manual to answer this question.

3. Adjust the scan parameters of the program until you obtain a well-centered spectrum that looks something like shown in Figure 4.
Figure 4: The Diode Scan of the transmission spectrum of the F-P analyzer (ACH0) and laser-induced fluorescence (ACH2)
On this picture, the ACH0 trace shows the transmission spectrum of the F-P analyzer. These are sometimes called "frequency markers"; more negative signal means more transmitted light. The ACH1 input is not used and terminated (for the time being) and the ACH2 trace represents the laser-induced fluorescence spectrum.
  • Note: If you see some signals from one channel showing up in another, this means that there is "cross-talk" within the DAQ. To alleviate this problem, make sure that all signal amplitudes are under 1V. You can do this by reducing the gain of the amplifier, or closing down the aperture. ACH3 and ACH4 (the data from the polarimeter, PD-1 and PD-2) are another common source of cross talk. If you are not using these channels, you may want to leave them unplugged. They can distort the florescence spectrum beyond recognition. If you are using these channels and they are producing cross-talk try rotating the Polaroid film attenuator to reduce the amount of light hitting the diodes in the polarimeter.

Q. Explain the shape of the fluorescence spectrum. Which transitions correspond to the four fluorescence peaks? What determines their separation? What determines the width of a peak? The first article in the reprints shows this scan with the peaks labeled.

4. As a final step in this part of the lab, observe the fluorescence in real time. It is nice to record the signals electronically, but nothing compares to actually seeing the light as it happens! Adjust the Diode Scan program parameters, so the total scan time is several seconds (e.g. set 200 points per scan and 3 acquisitions per point), and the scanning is continuous. Using the night vision telescope, look at the side of the vapor cell as the laser is scanning.

Q. Describe what you see and explain these observations.

Part 3: Doppler-free saturation spectroscopy

In this part, you will obtain the saturated absorption spectrum of the D2-line, which is free from Doppler broadening. Doppler broadening arises because of thermal motion of radiating atoms, and often constitutes a major part of the total width of a spectral line. It is assumed here that you have read the relevant reprints and references and are familiar with the basic ideas on how this works. Preston and Weiman's article "Doppler Free Saturated Absorption Spectroscopy: Laser Spectroscopy" is a good place to start.

  1. The setup for this section is the same as in part 2. This time connect the photodiode PD-3 via a 1 MΩ PD Load Resistor to the A/I input of the SR830 lock-in amplifier ("A" input should be selected). The reference frequency output (f) of the SR540 chopper controller should be connected to the REF IN input of the lock-in amplifier. The settings of the laser scan parameters, the chopper frequency, and the lock-in settings should all be consistent. You should optimize them for your particular experiment. Try these settings, and adjust them as necessary: lock-in time constant 30 ms, 12dB/Oct, AC coupling, sensitivity 100 mV, chopper frequency 400 Hz. Connect CH1 OUTPUT of the lock-in amplifier to the ACH1 data acquisition input (Breakout Box). Connect the DAC0 from the Breakout Box to the Feed Forward of the 2010 Servo Lock. Connect the DAC1 of the Breakout Box to the Input of the 2010 Servo Lock. Scan the laser and simultaneously observe the Doppler-broadened laser-induced fluorescence and the Doppler-free saturation spectroscopy signals. Record the data and include the corresponding graphs in your report. Note that the widths and intensities of the saturation spectroscopy resonances depend on the powers of the laser beams and on their relative polarization. These parameters can be adjusted and optimized using combinations of Polaroid film sheets.
  2. Zoom in on each of the four transition groups, using procedure described below. Record your scans. Note that for high-resolution scans, the discreteness of the computer DAQ may become a limiting factor. To avoid this problem, use a voltage divider (provided in a small copper box with two BNC connectors) to attenuate the DAQ control voltage.

Procedure for Zooming In

On the Diode scan program, set values for a scan which has an average voltage of 0 (e.g., Vmin=-1.5 and 3 Vpp), and press Start ONCE. (This will only set the values, but will not actually do a scan.) The reason for doing this is that even though the program is not scanning, it is still applying the average voltage to the servo-lock, which displays it. On the Servo-lock, turn the "meter select" knob to "output", and turn the bias knob until this display reads zero. This eliminates any output offset.

Now do a regular (non-zoomed) scan over all the peaks and note the voltages at each of them. Now set LabView to do a scan, which has an average voltage of 0, but don't start the scan yet (only press Start once). If for example, the first peak on the left of the scan has a voltage of .904V, turn the bias knob until the servo says 0.904V. Put in the 1:10 Divider (zoom resistor) and take another scan. What you've done is fool LabView into thinking that it is still sweeping near 0V with no offset, while the servo is outputting a sweep around 0.904V, right where the peak is. The zoomed-in peak should now show up in your scan- if it is off a little, you can center it by adjusting the bias knob or by adjusting the scan parameters in LabView. Repeat the process for the other three peaks.

Q. What is a cross-over resonance? Do you see such resonances in your saturation spectroscopy scans? What determines the width of the saturation spectroscopy resonances?

3. In the analysis stage of your experiment, based on the data that you have recorded, you can determine the isotope shift of the transition and the hyperfine structure constants for both upper and lower states of each Rb isotope. The frequency markers that you have recorded are important for absolute calibration of your scans. It is up to you to work out the detailed analysis procedure. Include a comprehensive description in your report. Compare your results with the literature data. Reading up on isotope shifts and hyperfine structure will take lots of time. Don't hesitate to talk with the laboratory instructors when needed.

Part 4: Optical polarimetry, nonlinear magneto optics

In this part of the lab, you will use a laser polarimeter to investigate the resonant Faraday effect in Rb vapor. The Faraday effect is the rotation of the direction of polarization of linearly polarized light as it passes through a medium that has a magnetic field applied parallel to the direction of light propagation. In this experiment, we use light reflected from the beam splitter BS-4 (Fig. 1). This light first goes through two pieces of Polaroid film. These are used as a variable attenuator to adjust the light power (Both pieces of film are set on one mount. One piece is free to rotate and the other is fixed. Rotating the movable piece changes the amount of light that gets through.) Next, the beam goes through a precision prism polarizer and through a Rb vapor cell installed inside the magnetic shield. Note that we have in the laboratory equipment box several different cells with different isotopic compositions. The one inside the shield is likely to contain pure 85Rb, rather than an isotopic mixture. Verify the isotopic composition by comparing the spectra from this cell with those from the cell outside the shields, which contains a natural isotopic mixture. A magnet coil is installed inside the inner shield. This set-up is used to shield the lab magnetic field and to produce a well-controlled field along the axis of the chamber. Next, the light beam is split by a polarizing beam splitter (PBS) also known as polarimeter. The two resulting beams fall onto photodiodes (PD-1 and PD-2) which detect their power.

Q. Estimate the value of the residual magnetic field at the vapor cell due to the Earth's and building's magnetic field. The article on magnetic shielding may be useful. Both layers of magnetic shielding are manufactured out of 0.04" (1 mm) thick sheet of the CONETIC-AA alloy with a magnetic permeability \mu=\frac{B}{H}\approx 10^5. Calculate the calibration factor (in Gs/A) relating the value of the magnetic field produced by the coil and its current. Reproduce these estimates and calculations in your report. Hint: the presence of the magnetic shield actually affects the field inside the coil.

To measure rotation of the plane of polarization in a sample, it is placed between two polarizers as shown in Figure 5, in what is called a balanced polarimeter. The Polarizer and Polarized Beam Splitter (PBS) have their transmission axes oriented at 45 degrees to one another.

Fig. 5. Schematic of a balanced polarimeter

Consider the two light beams emerging from the PBS and falling onto the photodiodes PD-1 and PD-2. The transmitted powers of these beams for an ideal lossless PBS is:

P1 = P0cos2θ
P2 = P0sin2θ
P0 = P1 + P2

where P0 is the light power entering the PBS, and θ is the angle between the polarization axis of the light and the PBS axis.

When the angle between the Polarizer and the PBS transmission axes is set to \frac{\pi}{4}, we have \theta=\frac{\pi}{4}+\delta, where δ is the angle of polarization rotation in the sample. Using trigonometric formulas and assuming that δ < < 1, we find that

\cos^2{\theta}=\frac{1+\cos{2\theta}}{2}, \sin^2{\theta}=\frac{1-\cos{2\theta}}{2}, \cos{\frac{\pi}{2}+2\delta}\approx -2\delta
P_1-P_2\approx 2\times P_0\times\delta=2\times(P_1+P_2)\times\delta

The optical rotation in the sample is then

\delta=\frac{P_1-P_2}{2(P_1+P_2)}

This equation is programmed into LabView ("B-field scan for 111 lab.vi").

Q. How would this result change if along with polarization rotation in the sample there were circular dichroism - unequal absorption for the right- and left-circular polarizations? Consider small rotation and dichroism, so the two effects can be treated independently.

4. Direct the laser beam from BS-4 into the magnetic shield assembly and the balanced polarimeter (see Fig. 2). Make sure that the beam is centered both on the input and the output of each element. It should be possible to achieve this by adjusting the beam splitter BS-4 and the relevant optical and magnetic shield assembly mounts.

Procedure for Aligning the Optical Rotation Equipment

2. With (PD-6 connected to ACH2) run a diode scan (the DAC0 from the Breakout Box should be connected to the Feed Forward of the 2010 Servo Lock and the DAC1 of the Breakout Box connected to the Input of the 2010 Servo Lock).
3. Repeat the scan but this time hit pause on LabView when the laser frequency is centered on the 85Rb Fg=3 level (the most prominent ground state level). This ensures that the rubidium sample inside the magnetic field chamber is fluorescing.
4. Next, connect the two outputs of the balance polarimeter (PD-1 and PD-2) to channel 1 and 2 on an oscilloscope and set the scope to add the channels together. Adjust the beam splitter, and the orientation and height of the polarimeter so that the voltage displayed on the scope is as negative as possible (negative voltage means light is hitting the diode).
5. Now, connect PD-1 to data acquisition input ACH3 and PD-2 to ACH4 via the 100 KΩ PD Load Resistance boxes. Connect the DAC1 output to the Input 1 of the COIL DRIVER. The Output 1 of the Coil Driver goes to the magnetic coil. Keep the DAC0 connected to the Servo Lock's Feed Forward input. The DAC1 output will be scanned by the computer in the range -5 to +5V. The current source produces an output current in the approximate range -1.5 to +1.5A, proportional to the voltage at its input. It will be necessary for you to obtain current calibration, i.e., to figure out precisely which current corresponds to a given DAC1 voltage. Hook up a multi-meter to the "Current Mon." connector of the Coil Driver. It registers 100mV for every Amp driven through the coil.
6. Magnetic field control in this experiment is accomplished with a LabView VI program "field scan for 111 lab". This program is nearly identical with the "Diode scan for 111 lab.vi" program. We use both programs simultaneously to tune the laser to the frequency at which we wish to take a B-field scan and to scan the magnetic field. When all necessary connections and beam alignment have been done, start the "Diode scan for 111 lab.vi" and take a single scan across the atomic resonance encompassing all four line groups. It should look something like Figure 6.
Figure 6: The B-Field Scan
7. Before proceeding further, you have to balance the polarimeter, i.e. make sure that the value of the "optical rotation angle" that you see when the laser is not on resonance is close to zero. Run the Diode Scan program and pause the laser frequency far from any peaks (press the Pause button on the front panel of the VI, not on the LabView task bar). The button text should change to Resume indicating that a repeated click on the button will resume the frequency scan. Then run the "B-field scan for 111 lab.vi." While the scan is running, adjust the angle of the PBS mount to zero the apparent optical rotation angle.
8. You are now ready to take Faraday effect data. Decide at which frequency point you would like to study the B-dependence of the Faraday rotation. A good first choice is the center of the F=3\rightarrowF' peak for 85Rb. Scan the laser frequency again and pause the scan on this peak. Now run the "B-field scan for 111 lab.vi". This allows you to set the magnetic field (i.e. DAC1) scan parameters and display raw signal from one of the photodiodes (PD-1, or PD-2). The optical rotation angle determined as discussed above, and the sum of signals of photodiodes (PD-1 and PD-2) is a measure of power of the laser beam after the sample.
9. Here is the second major assignment in this lab: investigate the magnetic field dependence of NLFR; demonstrate the existence of three contributions to NLFR (see Prerequisite Reading Materials for detailed discussion)): "hole burning", "transit effect", and the "wall-collision induced effect". IMPORTANT: The rubidium cell inside the magnetic shield is not coated so it is impossible to see the "wall-collision induced effect". If possible, determine the width of the peaks in the magnetic field dependence of the rotation corresponding to each of these mechanisms. How do these values compare with what might be expected? When you zoom onto the narrowest features in the magnetic field dependence of the optical rotation, you should not use the current source since because of its high gain, the resolution is limited by the discreteness of the computer DAC. Instead, connect the DAC (i.e. the signal used as input to the current source) to the magnetic coils through a 2.5 kΩ resistor (provided in a small blue box with two BNC connectors). This converts the DAC into a current source with I=VDAC/2.5 kΩ, where we neglect the small resistance of the magnetic coil.
  • Warning! Make sure that there is no current running through the coils when you break the circuit in order to add the resistor. When you break a circuit that contains an inductor (i.e. the magnetic coils) all the power contained in the inductor is dumped in the backward direction through the circuit, which can blow out the power supply.

Q. What is the magnitude of the linear Faraday rotation (the Macaluso-Corbino effect)? Is it observed in these experiments?

Personal tools